9. Valve will not draw brine. a. Low water pressure a. Fit pump (contact dealer)
b. Drain line restriced. b. Check the drain line is not blocked
or kinked.
c. Injector plugged. c. Clean injector and screen.
d. Injector defective. d. Replace injector.
e. Air check closes prematurely. e. Put control into brine draw C2 to
check. Repair or replace if needed.
10. Uses more or less salt than a. Foreign matter in valve causing a. Remove brine control and flush out
setting. incorrect flow rates. any debris. Put system through a
regeneration to flush valve.
11. No water flow display on a. Bypass valve in bypass. a. Open bypass.
metered valves. b. Meter probe not connected to b. Connect correctly.
control or turbine housing.
c. Restricted turbine rotation due c. Remove and clean turbine, Turbine
to foreign matter in turbine. should spin freely, if not replace.
12. Run out of conditioned water a. Impropper regeneration. a. Repeat regeneration after checking
between regenerations. the correct regenerant doseage is
set.
b. Incorrect regenerant setting. b. Set correct salt setting.
c. Incorrect hardness or capacity c. Set to correct values.
settings.
d. Water hardness has increased. d. Set hardness to new value.
e. Restricted turbine rotation e. See 11.c