System Characteristics
System Description, Autroprime Interactive Fire Detection System, 116-P-APRIME-SYSTEMD/XGB 2007-10-10,
Autronica Fire and Security AS
Page 4
2. System Characteristics
2.1 System Overview
Autroprime is a stand-alone fire detection system.
The Fire Alarm Control Panel supports 2 detection loops (the maritime
variant supports 4 detection loops). All loop units can be mixed freely
and connected at any point on the same detection loop.
A maximum of 8 additional panels can be freely mixed and connected
to the Fire Alarm Control Panel via the RS-485 panel bus, including
Repeater Panels BS-211, Information Panels BV-210,
Fire Brigade Panels BU-210 and Mimic Drivers BUR-200.
For information on system capacity, refer to chapter
2.8.
Fire Alarm Control Panel BS-200
ESPA 444 Communication Protocol or
NMEA protocol for VDR systems (RS-232, RS-422/485)