15
[2 #] -
Disarm control panel
. The control panel will be disarmed. A confirmation tune followed
by a "disarmed" tune will be sounded ("Disarmed" tune: Five short beeps).
[31 #] -
Activates A1
output for 3 seconds (enabled by programming 074-2)
[6 #] -
Stop dialer.
The dialer will stop calling the programmed telephone numbers. This will
affect only the current dialing process. A new alarm will re-start the dialer.
Note that if the user answered a call from the panel or called the panel during a dialing period
without Arming/Disarming/Stopping the dialer, the dialer will restart the cycle from the
beginning.
[7 #] -
Check control panel status
. The control panel will answer with an Armed or Disarmed
tune followed by an Alarm tune if it is in an alarm condition.
[7 and 7 #] -
First Alarm zone,
beeps count for the zone number. Report user the first zone that
caused alarm. Arming or Disarming clears the First alarm zone reported by DTMF.
[8X #] -
Learn function
. Using this command, the user can become familiar with the various
sounds used by the control panel in the remote access procedure. Further details find in the
dedicated paragraph. (X - The required sound).
[9 #] -
End call.
The control panel will sound a confirmation tune and will hang up.
15. USER CODE PROGRAMMING
Set New USER-CODE
1. Hold down key
2. While 4 LEDs are blinking, enter code No. 1 (default 1, 2, 3, 4)
3. If code is valid, four LEDs will stop blinking, and ‘u’ will be displayed
4. The two left-most LEDs blink to indicate that the system is waiting for a new user code index
(user 1 to 8) to be entered.
5. Enter the code index (1 for code No. 1; 2 for code No. 2, etc.)
6. The two right-most LEDs blink to indicate that the system is waiting for a new code
(1 to 6 digits) to be entered.
Not entering a user code is, voids the code.
7. Enter the new code; ‘U’ is displayed for confirmation.
8. To quit code setting hold-down key ‘9’.
Set new USER-CODE in Installer program mode
1. While system is in program mode, enter address 099, ‘u’ will be displayed
2. The two left-most LEDs blink to indicate that the system is waiting for a new user code index
(user 1 to 8) to be entered.
3. The two right-most LEDs blink to indicate that the system is waiting for a new code
(1 to 6 digits) to be entered. Enter the new code.
4. At Installer program mode, Installer Code (code no. 9) can be set. Installer Code index number
is ‘9’.
5. Upon code setting completion, system reverts to Disarm mode.
Delete a USER-CODE
1. Hold down key
2. While four LEDs are blinking, enter code No. 1 (default 1, 2, 3, 4)
3. If code is valid, four LEDs will stop blinking, and ‘u’ will be displayed