20
5.2.1 POOLeasy settings in pH mode
To set your POOLeasy in pH mode, refer to the previous section (5.0)
Flowrate setting for pump on the unit
Setting of number of calibration points (1 or 2). The
single calibration point is at pH 7.
Choice of reagent for dosing between
acid (pH-) and alkaline (pH+)
PUMP ACT. TIME
20 s/0.1pH
Setting of pump activation time in
steps of pH 0.1, for correction
OVERDOSING ALARM
0.5 L/4 Hrs
Setting of overdosing alarm: refer to
Section 5.2.4
MEASUREMENT
ADJUST
0.00 pH
Adjustment of the displayed value by + or ā pH 0.40.
CAUTION: improper use of this parameter may
result in erroneous dosing.
Allows the enabling/disabling of the 230V input
corresponding to the enabling of the filtration
pump. It is the input that corresponds to cable "i"
defined in Step 13 of the installation procedure.
Allows unit reinitialization.
By selecting YES, a confirmation will follow.
Return to language selection menu.
Press MENU/ESC to exit the menu.