34 Placing Conditioner Into Operation
Rev C
A. Slowly open the main water supply valve again, to the fully open
position. Be sure not to open too rapidly as that would push the
media out of the media tank.
B. With the water supply completely open, when you arrive at the
brine tank refill cycle, the controller will direct water down through
the line to the regenerant tank. Let the water flow through the line
until all air bubbles have been purged from the line.
C. Do not let the water flow down the line to the tank for more than one
to two minutes, or the tank may overfill.
D. Simultaneously press and release the SET and UP buttons to
advance to the Brine Prep cycle. After the Brine Prep cycle is
reached, press the SET and UP buttons to advance to the Brine
Draw/Slow Rinse cycle.
10. Draw water from the regenerant tank.
A. With the controller in this position, check to see that the water in the
regenerant tank is being drawn out of the tank. The water level in
the tank should recede very slowly.
B. Observe the water being drawn from the regenerant tank for at
least three minutes. If the water level does not recede, or goes up,
refer to the Troubleshooting section.
11. If the water level is receding from the regenerant tank press the SET
and the UP buttons to advance the controller back to the treated
water position.
12. Finally, turn on a faucet plumbed after the water conditioner. Run the
faucet until the water runs clear.
NOTE: As you advance through each cycle there will be a slight delay
before you can advance to the next cycle. There will be a pause after
the brine draw and slow rinse cycles (system pause). This cycle allows
the water/air pressure to equalize on each side of the valve discs before
moving on.