Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
10/2020
Refrigerated Chef Base Units
178CBE36HC, 178CBE48HC, 178CBE52HC, 178CBE60HC, 178CBE72HC,
178CBE84HC

Questions and Answers

  • B
    boydsaraJul 25, 2025
    Why is my Avantco 178CBE60HC cabinet temperature too warm?
    • M
      meghan61Jul 26, 2025
      Several factors can cause this. The thermostat might be set too warm, so try setting it to a lower temperature. Blocked airflow can also be the culprit; rearrange the product to allow proper airflow, ensuring at least four inches of clearance from the evaporator. Additionally, putting too much warm product in the cabinet can raise the temperature; allow adequate time for the product to cool down. A blown fuse or tripped circuit breaker could also be the cause; replace the fuse or reset the circuit breaker. A dirty condenser coil can also cause this problem, so clean the condenser coil. Finally, an iced-over evaporator coil might be the reason; ensure drawers are closed when not in use and avoid opening drawers for long periods of time.
  • T
    Tara GarciaAug 5, 2025
    Why does my Avantco Commercial Food Equipment condensing unit run for long periods of time?
    • C
      cmccoyAug 5, 2025
      Several factors can cause this issue. An excessive amount of warm product placed in the cabinet might be the cause; allow adequate time for the product to cool down. Prolonged drawer opening or a drawer left ajar can also lead to this; ensure drawers are closed when not in use and avoid opening them for long periods. Another reason might be drawer gaskets not sealing properly; ensure gaskets are snapped in completely, remove them and wash them with soap and water, and replace them if necessary. A dirty condenser coil can also cause this; clean the condenser coil. Finally, an iced-over evaporator coil could be the problem; unplug the unit and allow the coil to defrost, make sure the thermostat is not set too cold, and ensure that the door gaskets are sealing properly.
  • M
    Mark KramerAug 14, 2025
    What to do if the compressor is not running on my Avantco 178CBE60HC?
    • J
      Joseph McintyreAug 15, 2025
      If the compressor isn't running, start by checking the fuse or circuit breaker; replace the fuse or reset the circuit breaker if needed. Ensure the power cord is properly plugged in. Also, check the thermostat setting; if it's set too high, lower the temperature. Finally, if the cabinet is in defrost cycle, wait for it to finish.

Summary

Warning

Installation

Cabinet Location Guidelines

Guidance on placing the unit for optimal performance and stability.

Electrical

Requirements for proper power connection and outlet usage.

Temperature Controls

Adjusting the Temperature

Steps to modify the unit's temperature settings for refrigerators and freezers.

Digital Control Units

Instructions for operating the digital interface to set temperature.

Running a Manual Defrost Cycle

Defrost Systems

Loading Food Pans

Top Surface Dimensions

Drawer Configuration Diagrams

Safety; Warning

Attention

General safety precautions for operation and handling to prevent hazards.

Unplug Cord

Guidelines for safely unplugging the unit during maintenance or non-use.

Proper Grounding Required

Importance of correct grounding to prevent electrical hazards.

Warning

Specific warnings against unauthorized repairs and improper use.

Regular Maintenance

Cleaning The Condenser Coil

Instructions for cleaning the condenser coil for efficient operation.

Cleaning The Fan Blades and Motor

Method for cleaning fan blades and motor, protecting the motor from moisture.

Cleaning The Interior of Unit

Procedures for cleaning the cabinet interior and drawer gaskets.

Troubleshooting

Compressor Not Running

Common issues and solutions when the compressor fails to start.

Condensing Units Run For Long Periods of Time.

Troubleshooting for continuous operation of condensing units.

Cabinet Temperature is too Warm.

Solutions for issues causing the cabinet temperature to be too high.

Warranty Information

Limited Service Warranty - Valid only in the United States - 10;2020

Details of the limited service warranty, including duration and coverage.

3 Year Parts and Labor Warranty

Warranty coverage for parts and labor for a period of three years.

2 Year Parts and Labor Warranty

Warranty coverage for parts and labor for a period of two years.

1 Year Parts and Labor Warranty

Warranty coverage for parts and labor for a period of one year.

5 Year Compressor Warranty

Extended warranty specifically for the compressor component.

For Warranty Inquiries or Service:

Food Truck and Outdoor Commercial Use Warranty:

Avantco 178CBE60HC Specifications

General IconGeneral
BrandAvantco
Model178CBE60HC
CategoryCommercial Food Equipment
LanguageEnglish

Related product manuals