EasyManua.ls Logo

Avantco SS-3R-HC - User Manual

Avantco SS-3R-HC
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
User Manual
05/2023
SS Series Reach-In
Refrigerators and Freezers
Models:
Refrigerator Models
#178SS1RHC 29" Solid Door
#178SS2RHC 54" Solid Door
#178SS3RHC 81" Solid Door
#178SS1RGHC 29" Glass Door
#178SS2RGHC 54" Glass Door
#178SS1R2HC 29" Solid Half Door
#178SS2R4HC 54" Solid Half Door
Freezer Models
#178SS1FHC 29" Solid Door
#178SS2FHC 54" Solid Door
#178SS3FHC 81" Solid Door
#178SS1F2HC 29" Solid Half Door
#178SS2F4HC 54" Solid Half Door
Note:
You should read this manual in its entirety prior to equipment setup, operation, and maintenance.
www.AvantcoRefrigeration.com

Other manuals for Avantco SS-3R-HC

Questions and Answers

  • M
    Mark RogersAug 15, 2025
    Why is my Avantco SS-3R-HC Refrigerator cabinet temperature too warm?
    • R
      rachelallenAug 15, 2025
      Several factors can cause a too warm cabinet temperature: * The thermostat might be set too high; lower the thermostat setting. * Airflow could be blocked; rearrange items to allow proper airflow, ensuring at least four inches of clearance from the fan. * Low refrigerant levels can be a factor; contact a service technician to check refrigerant levels. * The door might not be fully closed; ensure the door is completely closed.
  • C
    Carl MoralesAug 18, 2025
    Why is my Avantco Freezer's cabinet temperature too warm?
    • M
      muellerjackAug 18, 2025
      If the Avantco Freezer's cabinet temperature is too warm, there might be several reasons. First, check if the thermostat is set too warm and lower the temperature if needed. Also, ensure that airflow isn't blocked by rearranging the product inside, providing at least 4" of clearance from the evaporator. Avoid placing an excessive amount of warm product in the cabinet. Other potential causes include a blown fuse or tripped circuit breaker (replace or reset), a dirty condenser coil (clean it), an iced-over evaporator coil (close doors and defrost), a door slightly ajar (close it completely), or low refrigerant levels (contact a service technician).
  • A
    audreyfranklinAug 22, 2025
    What to do if the compressor is not running on my Avantco Freezer?
    • S
      Stephanie JonesAug 22, 2025
      If the compressor on your Avantco Freezer isn't running, first check the basics: ensure the power cord is plugged in. Then, check the fuse and circuit breaker; replace the fuse or reset the breaker if necessary. Also, make sure the thermostat isn't set too high by setting the thermostat to a lower temperature. Finally, the unit might be in a defrost cycle, so wait for it to finish.
  • C
    Carmen SchroederAug 25, 2025
    Why do the condensing units run for long periods of time on my Avantco Freezer?
    • G
      gary67Aug 26, 2025
      If the condensing units of your Avantco Freezer run for extended periods, it could be due to several factors. An excessive amount of water product in the cabinet might be the reason, so allow adequate time for the product to cool down. Check if the doors are being opened frequently or left ajar; ensure they are closed when not in use and avoid prolonged openings. Inspect the door gaskets for proper sealing; make sure they are snapped in completely, and clean them with soap and water, replacing if necessary. A dirty condenser coil can also cause this issue, so clean it. Lastly, an iced-over evaporator coil can be the culprit; unplug the unit to defrost the coil, ensure the thermostat isn't set too cold, and verify that the door gaskets are sealing correctly.
  • J
    John ShafferAug 28, 2025
    Why is condensation collecting on my Avantco Freezer cabinet and/or floor?
    • K
      Kristin LopezAug 28, 2025
      If condensation is collecting on your Avantco Freezer's cabinet or floor, the gasket might not be sealing properly; clean, repair, or replace it as needed. Another cause might be that the relative humidity is above 60%; move the unit to an area with lower relative humidity, or lower the humidity level in the current area.
  • R
    Robert Mann DDSSep 1, 2025
    How to fix the interior light on my Avantco Freezer?
    • H
      Heather SchaeferSep 1, 2025
      If the interior light of your Avantco Freezer isn't working, first try turning the light switch off and then back on to address a poor switch connection. If that doesn't work, check if the bulb is correctly inserted in the socket. If the bulb is properly connected, it may have burned out, so replace the bulb.
  • B
    Brittany RiddleSep 4, 2025
    What to do if the Avantco Refrigerator compressor is not running?
    • M
      Mr. Robert ThompsonSep 4, 2025
      If the compressor isn't running, check the following: * Ensure the fuse hasn't blown or the circuit breaker hasn't tripped; replace the fuse or reset the breaker if needed. * Verify the power cord is plugged in. * Make sure the thermostat isn't set too high; set it to a lower temperature. * If the unit is in defrost cycle, wait for it to finish.
  • J
    James KnightSep 7, 2025
    What to do if the interior light is not working in my Avantco Refrigerator?
    • B
      Bethany HudsonSep 7, 2025
      If the interior light isn't working, try these steps: * Turn off the light switch and turn it back on to check the switch connection. * Ensure the bulb is correctly inserted in the socket. * Replace the bulb if it has burned out.
  • C
    Cynthia AndersonSep 12, 2025
    How to fix condensation collecting on the Avantco Refrigerator cabinet or floor?
    • S
      Shannon ScottSep 12, 2025
      If condensation is collecting, it's likely due to the gasket not sealing properly. Clean, repair, or replace the gasket as necessary.

Avantco SS-3R-HC Specifications

General IconGeneral
Number of Doors3
Cooling SystemForced Air
Exterior MaterialStainless Steel
Interior MaterialAluminum
RefrigerantR290
Voltage115V
Phase1
Amps8.5
TypeReach-In
Temperature Range33°F to 40°F (0.6°C to 4.4°C)
Shelf MaterialEpoxy Coated Wire
Horsepower1/2 hp

Related product manuals