Connecting AC power
Required cable: AC power cord that meets the requirements of your local electrical code. Refer
to the following table for plug specifications.
Table 1: International power cord specifications
Country and plug description Specifications Typical plug
Continental Europe
CEE7 standard VII male plug
Harmonized cord (HAR marking on
the outside of the cord jacket to
comply with the CENELEC
Harmonized Document HD-21)
220 or 230 VAC
50 Hz
Single phase
U.S./Canada/Japan
NEMA5-15P male plug
UL-recognized (UL stamped on
cord jacket)
CSA-certified (CSA label secured
to the cord)
100 or 120 VAC
50-60 Hz
Single phase
United Kingdom
BS1363 male plug with fuse
Harmonized cord
240 VAC
50 Hz
Single phase
Australia
AS3112-1981 male plug
240 VAC
50 Hz
Single phase
The Ethernet Routing Switch 4000 Series does not have a power switch. When you connect
the AC power cord to a suitable AC power outlet, the switch powers up immediately.
Installation preparation
10 November 2013