143
7ELECTRONICS DESCRIPTION
7.5 SIGNAL INTERFACE
ALS
20X
256
7.5.4
Applicator type <--> Signals
[153] Signals which are used by the different applicator types
(X = signal applied)
1) Only used with LTPV
2) Only used with pneumatic dispensing edge
3) Signal only at optional Applicator Interface
For details about applicator types read the de-
scription of function
SIGNAL INTERFACE >APPLIC.
SIGNALS > Applicator type
on Seite 58.
Signal Applicator
LTP(V)
PEP IV
PEP Blow on
PEP II Sens.
ASA
Rev. PEP
Direct Dispense
BTS
O-Ring appl.
LA-BO
LA-TO timed.
LA-TO sensor
Inputs:
Home Position X X X X -- X -- X X -- X X
Touch Down X -- -- X -- -- -- -- X -- -- X
Out-
puts:
Airstream Support X X X X X X X
2
--XXXX
Vacuum X
1
-- X X X X -- -- X -- -- --
Cylinder X X X X -- X -- X X -- X X
Blow On X -- X X X X -- -- X X -- --
+24V for fan X X X X -- -- -- -- X -- -- --
BTS
3