Power Supplies
26
Avid NEXIS | E5 and Avid NEXIS | E5 NL Fans
Avid NEXIS | E5 and Avid NEXIS | E5 NL Fan LED Status
On On Off PSU alert state (usually due to reaching critical
temperature)
Off On Off Mains AC to this PSU is missing (This PSU is on standby,
other PSU is OK)
On On On GEM software has lost communication with PSU
On --- Off PSU has failed
2200W PSU LED Status
PSU Fail
(Amber)
AC Fail
(Amber)
Power OK
(Green) Status
Fan OK
(Green)
Battery fault
(Amber)
Fan fault
(Amber) Status
--- --- Off Fan OK
--- --- On Communication lost with fan module controller
--- --- On Reported fan speed is out of tolerance
On Off --- Fan and battery OK
Flashing Off --- Battery charging
Off On --- Battery fault
On --- Off PSU has failed