When an operator answers an alarm call, the Memcom
+
will
automatically play the location message.
NOTE: when programming in the alarm numbers
‘UNGUIDED’ protocol must be selected (see section on Alarm
Numbers for more detail).
Avoid Silence
x
ü
During an alarm call the Memcom
+
will not mute its speaker,
unless the operator presses the ‘2’ key on their handset.
Quick Dial
x
ü
Reduces the dial tone detection test from 7 seconds to 3
seconds – prevents issues with exchanges timing out after 4
seconds.
Quick VAD.
x
ü
Allows the Memcom
+
to detect speech before the rst ring
pulse has been sent down the line.
Dialtone req
x
ü
Requires the Memcom
+
to detect a dial tone before it attempts
to dial out.
Linet. Alert
x
ü
If the phone line to the Memcom
+
is cut, the unit will play an
audible warning message. The message will repeat every 3
minutes unit the phone line is restored.
Hotline
x
ü
Tells the Memcom it is connected to a hotline, allowing any
other of the call protocols to then be selected for use on that
line.
Menu Sections
System Cong+
Hardware (HW) Monitoring
Hardware monitoring sets which system elements are checked when
the unit completes its self-check and places a test call. Default
settings are shown below:
Full Programming Options
Power Supply
ü
Battery
ü
Phone Line
ü
GSM low sig.
û
GSM no sig.
û
Spkr/mic.
ü
GSM Status
û