EasyManua.ls Logo

AVS A Series - Programming Features Register 2

Default Icon
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AVS A-SERIES INSTALLATION MANUAL - GEN 2 VER 5
22
Programming features Register 1 continued
Vehicle set up: Close all doors, bonnet & boot, arm & disarm alarm then turn ignition on, off & on.
Feature:
MAP feature 2-second entry delay / Factory remote interface mode (old
OEM Enhancement module) / Split lock & unlock button mode
Press the button
this many times:
19
Factory setting:
OFF
Description:
This feature delays the doors, boot etc for two seconds. Use if the door light
comes on before the door unlocks.
When this feature is ON it also allows the old style OEM Enhancement module
to work. Note: if using this module the alarm will now arm on button and
disarm on when using AVS remote.
Feature:
Courier Mode
Press the button
this many times:
20
Factory setting:
OFF
Description:
Courier mode allows the driver to leave the ignition on with the engine running
and arm the alarm. The alarm will be fully armed three seconds after pressing
the button. If the alarm is activated the system will shut the engine down
and trigger as normal.
When in courier mode the glass sensor (AVS A5) will be disabled while the
engine is running but will arm normally when the ignition is off. Note AUX input
remains active
Note: The ignition must be on for more than 5 seconds before the alarm can be
armed.
Programming functions Register 2
Vehicle set up: Open a door, close bonnet & boot, arm & disarm alarm then turn ignition on, off & on.
Feature:
Digital glass break sensor (A5 only)
Press the button
this many times:
3
Factory setting:
ON
Description:
Turn this feature OFF to disable the digital glass break sensor.
Feature:
Automatic re-arm and re-lock
Press the button
this many times:
4
Factory setting:
OFF

Table of Contents