EasyManua.ls Logo

Axel WOLF - Page 38

Default Icon
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WOLF NETWORK CONFIGURATION IMPORT / EXPORT FILE
Axel Technology |
38
set, an alarm is generated.
62
ALARM_MPX_1_DEC_AUDIO_THR_LOW=No_Inf_Li
mit
This parameter sets the DECoded audio
measurement value at the MPX-1 input. If the
measurement is below the value set, an alarm
is generated.
No_Inf_Limit = control
disabled
(see protocol)
63
ALARM_MPX_1_DEC_AUDIO_THR_HIGH=+3.0dB
This parameter sets the DECoded audio
measurement value at the MPX-1 input. If the
measurement is above the value set, an alarm
is generated.
64
ALARM_MPX_1_DEC_AUDIO_SILENCE_THR=-
40.0dB
This parameter sets the minimum audio
threshold value at the MPX-1 Decoder input
below which the sound is considered silence.
65
ALARM_MPX_1_DEC_AUDIO_SILENCE_TIME=5sec
This parameter specifies how long (in seconds)
before an audio level at MPX-1 DECoder input
below the "ALARM_AUDIO_SILENCE_THR ="
value should be considered silence, in which
case an alarm will be generated.
66
ALARM_MPX_2_PILOT_THR_LOW=-23.5dB
This parameter sets the stereophonic pilot
carrier (19Hz) measurement value at the MPX-
2 input. If the measurement is below the value
set, an alarm is generated.
67
ALARM_MPX_2_PILOT_THR_HIGH=-20.5dB
This parameter sets the stereophonic pilot
carrier (19Hz) measurement value at the MPX-
2 input. If the measurement is below the value
set, an alarm is generated.
68
ALARM_MPX_2_PILOT_PROT_THR=-45.0dB
This parameter sets the pilot protection
measurement value, i.e. the purity (presence or
absence of spurious and harmonic emissions,
disturbance…) around the 19Hz frequency or
the stereophonic pilot. The measurement is
taken at the MPX-2 input. If the measurement is
above the value set, an alarm is generated.
69
ALARM_MPX_2_RDS_THR_LOW=-28.5dB
This parameter sets the RDS data carrier (57
Hz) measurement value at the MPX-2 input. If
the measurement is below the value set, an
alarm is generated.
70
ALARM_MPX_2_RDS_THR_HIGH=-26.5dB
This parameter sets the RDS data carrier (57
Hz) measurement value at the MPX-2 input. If
the measurement is below the value set, an
alarm is generated.
71
ALARM_MPX_2_PEAK_DEV_THR_LOW=No_Inf_Lim
it
This parameter sets the Peak deviation of the
MPX signal at the MPX-2 input. If the
measurement is below the value set, an alarm
is generated.
72
ALARM_MPX_2_PEAK_DEV_THR_HIGH=90KHz
This parameter sets the Peak deviation of the
MPX signal at the MPX-2 input. If the
measurement is above the value set, an alarm
is generated.
73
ALARM_MPX_2_ITUB412_THR_LOW=No_Inf_Limi
t
This parameter sets the MPX Power (19Hz)
measurement value (expressed as
recommendations ITU BS 412) at the MPX-2
input. If the measurement is below the value
set, an alarm is generated.
74
ALARM_MPX_2_ITUB412_THR_HIGH=No_Sup_Lim
it
This parameter sets the MPX Power (19Hz)
measurement value (expressed as
recommendations ITU BS 412) at the MPX-2
input. If the measurement is above the value
set, an alarm is generated.
75
ALARM_MPX_2_DEC_AUDIO_THR_LOW=No_Inf_Li
mit
This parameter sets the DECoded audio
measurement value at the MPX-2 input. If the
measurement is below the value set, an alarm
is generated.
76
ALARM_MPX_2_DEC_AUDIO_THR_HIGH=+3.0dB
This parameter sets the DECoded audio
measurement value at the MPX-2 input. If the
measurement is above the value set, an alarm
is generated.