WOLF NETWORK CONFIGURATION IMPORT / EXPORT FILE
ALARM_MPX_2_DEC_AUDIO_SILENCE_THR=-
40.0dB
This parameter sets the minimum audio
threshold value at the MPX-2 DECoder input
below which the sound is considered silence.
ALARM_MPX_2_DEC_AUDIO_SILENCE_TIME=5sec
This parameter specifies how long (in seconds)
before an audio level at MPX-2 DECoder input
below the "ALARM_AUDIO_SILENCE_THR="
value should be considered silence, in which
case an alarm will be generated
ALARM_FM_MPX_PILOT_THR_LOW=-23.5dB
This parameter sets the stereophonic pilot
carrier (19Hz) measurement value at the FM
input (Monitor-RF). If the measurement is below
the value set, an alarm is generated.
ALARM_FM_MPX_PILOT_THR_HIGH=-21.5dB
This parameter sets the stereophonic pilot
carrier (19Hz) measurement value at the FM
input (Monitor-RF). If the measurement is
above the value set, an alarm is generated.
ALARM_FM_MPX_PILOT_PROT_THR=-35.0dB
This parameter sets the pilot protection
measurement value, i.e. the purity (presence or
absence of spurious and harmonic emissions,
disturbance…) around the 19Hz frequency or
the stereophonic pilot. The measurement is
taken at the FM input (Monitor-RF). If the
measurement is above the value set, an alarm
is generated.
ALARM_FM_MPX_RDS_THR_LOW=-28.5dB
This parameter sets the RDS data carrier (57
Hz) measurement value at the FM input
(Monitor-RF). If the measurement is below the
value set, an alarm is generated.
ALARM_FM_MPX_RDS_THR_HIGH=-26.5dB
This parameter sets the RDS data carrier 57
Hz) measurement value at the FM input
(Monitor-RF). If the measurement is above the
value set, an alarm is generated.
ALARM_FM_MPX_PEAK_DEV_THR_LOW=No_Inf_Li
mit
This parameter sets the Peak deviation of the
MPX signal at the FM input (Monitor-RF). If the
measurement is below the value set, an alarm
is generated.
ALARM_FM_MPX_PEAK_DEV_THR_HIGH=90KHz
This parameter sets the Peak deviation of the
MPX signal at the FM input (Monitor-RF). If the
measurement is above the value set, an alarm
is generated.
ALARM_FM_MPX_ITUB412_THR_LOW=No_Inf_Lim
it
This parameter sets the MPX Power
measurement value (expressed as
recommendations ITU BS 412) at the FM input
(Monitor-RF). If the measurement is below the
value set, an alarm is generated.
ALARM_FM_MPX_ITUB412_THR_HIGH=No_Sup_Li
mit
This parameter sets the MPX Power
measurement value (expressed as
recommendations ITU BS 412) at the FM input
(Monitor-RF). If the measurement is above the
value set, an alarm is generated.
ALARM_FM_MPX_DEC_AUDIO_PEAK_THR_LOW=No_
Inf_Limit
This parameter sets the Peak DECoded audio
measurement value at the FM input (Monitor-
RF). If the measurement is below the value set,
an alarm is generated.
ALARM_FM_MPX_DEC_AUDIO_PEAK_THR_HIGH=+3
.0dB
This parameter sets the Peak DECoded audio
measurement value at the FM input (Monitor-
RF). If the measurement is above the value set,
an alarm is generated.
ALARM_FM_MPX_DEC_AUDIO_PEAK_SILENCE_THR
=-40.0dB
This parameter sets the minimum audio
threshold value at the FM DECoder input
(Monitor-RF) below which the sound is
considered silence.
ALARM_FM_MPX_DEC_AUDIO_PEAK_SILENCE_TIM
E=5sec
This parameter specifies how long (in seconds)
before an audio level at FM DECoder input
(Monitor-RF) below the
"ALARM_AUDIO_SILENCE_THR=" value should