WOLF NETWORK CONFIGURATION IMPORT / EXPORT FILE
Axel Technology |
40
be considered silence, in which case an alarm
will be generated
92
ALARM_MPX_0_PILOT_THR_LOW=-23.5dB
This parameter sets the stereophonic pilot
carrier (19 Hz) measurement value at the MPX-
0 input. If the measurement is below the value
set, an alarm is generated.
93
ALARM_MPX_0_PILOT_THR_HIGH=-21.5dB
This parameter sets the stereophonic pilot
carrier (19 Hz) measurement value at the MPX-
0 input. If the measurement is below the value
set, an alarm is generated.
94
ALARM_MPX_0_PILOT_PROT_THR=-50.0dB
This parameter sets the pilot protection
measurement value, i.e. the purity (presence or
absence of spurious and harmonic emissions,
disturbance…) around the 19Hz frequency or
the stereophonic pilot. The measurement is
taken at the FM input (Monitor-RF). If the
measurement is above the value set, an alarm
is generated.
95
ALARM_MPX_0_RDS_THR_LOW=-28.5dB
This parameter sets the RDS data carrier (57
Hz) measurement value at the MPX-0 input. If
the measurement is below the value set, an
alarm is generated.
96
ALARM_MPX_0_RDS_THR_HIGH=-26.5dB
This parameter sets the RDS data carrier (57
Hz) measurement value at the MPX-0 input. If
the measurement is above the value set an
alarm is generated.
97
ALARM_MPX_0_PEAK_DEV_THR_LOW=No_Inf_Lim
it
This parameter sets the Peak deviation of the
MPX signal at the MPX-0 input. If the
measurement is below the value set an alarm is
generated.
98
ALARM_MPX_0_PEAK_DEV_THR_HIGH=90KHz
This parameter sets the Peak deviation of the
MPX signal at the MPX-0 input. If the
measurement is above the value set, an alarm
is generated.
99
ALARM_MPX_0_ITUB412_THR_LOW=No_Inf_Limi
t
This parameter sets the MPX-0 Power (19 Hz)
measurement value (expressed as
recommendations ITU BS 412) at the MPX-0
input. If the measurement is below the value
set, an alarm is generated.
100
ALARM_MPX_0_ITUB412_THR_HIGH=No_Sup_Lim
it
This parameter sets the MPX-0 Power (19Hz)
measurement value (expressed as
recommendations ITU BS 412) at the MPX-0
input. If the measurement is above the value
set, an alarm is generated.
101
ALARM_MPX_0_DEC_AUDIO_PEAK_THR_LOW=No_I
nf_Limit
This parameter sets the Peak DECoded audio
measurement value at the MPX-0 input. If the
measurement is below the value set, an alarm
is generated.
102
ALARM_MPX_0_DEC_AUDIO_PEAK_THR_HIGH=+1.
0dB
This parameter sets the Peak DECoded audio
measurement value at the MPX-0 input. If the
measurement is above the value set an alarm
is generated.
103
ALARM_MPX_0_DEC_AUDIO_PEAK_SILENCE_THR=
-40.0dB
This parameter sets the minimum audio
threshold value at the MPX-0 DECoder input
below which the sound is considered silence.
104
ALARM_MPX_0_DEC_AUDIO_PEAK_SILENCE_TIME
=5sec
This parameter specifies how long (in seconds)
before an audio level at MPX-0 DECoder input
below the "ALARM_AUDIO_SILENCE_THR="
value should be considered silence, in which
case an alarm will be generated.
105
AUTO_RDS_DECODER_SOURCE_SEL=Mpx1
This parameter specifies which MPX source
should be connected to the RDS decoder in
order to view, control and monitor RDS data.
106
AUTO_TUNER_FREQUENCY=100.80MHz
In this parameter you can set the tuning