WOLF NETWORK CONFIGURATION IMPORT / EXPORT FILE
This parameter is used to display (or not) the
decoded audio control (expressed as RMS)
from the MPX-2 input.
This parameter is used to display (or not) the
stereophonic pilot (19 Hz) at the FM input
(Monitor-RF).
This parameter is used to display (or not) the
RDS service (57 Hz) at the FM input (Monitor-
RF).
This parameter is used to display (or not)
“Excess or No deviation” errors at the FM input
(Monitor-RF).
This parameter is used to display (or not) ITU-
R BS412 errors at the FM input (Monitor-RF).
FM_MPX_PILOT_PROTECTION=On
This parameter is used to display (or not) Pilot
Protection control errors at the FM input
(Monitor-RF).
FM_MPX_DECODER_SILENCE=On
This parameter is used to display (or not) the
decoded audio control (intended as the
presence of silence) from the FM input
(Monitor-RF).
This parameter is used to display (or not) the
decoded audio control (expressed as RMS)
from the FM input (Monitor-RF).
This parameter is used to display (or not) the
stereophonic pilot (19 Hz) at the MPX-0 input.
This parameter is used to display (or not) the
RDs service (57 Hz) at the MPX-0 input.
This parameter is used to display (or not)
“Excess or No deviation” errors at the MPX-0
input.
This parameter is used to display (or not) ITU-
R BS412 errors at the MPX-0 input.
This parameter is used to display (or not) Pilot
Protection control errors at the MPX-0 input.
This parameter is used to display (or not) the
decoded audio control (intended as the
presence of silence) from the MPX-0 input.
This parameter is used to display (or not) the
Peak decoded audio control from the MPX-0
input.
Alarm generation and display re. quality of the
RDS service (expressed as a %)
Inherent to the MAIN input
Alarm generation and display re. PI control. If
this does not match the setting, an alarm is
generated.
Inherent to the MAIN input
Alarm generation and display re. DI control. If
this does not match the setting, an alarm is
generated
Alarm generation and display re. Program Type
control. If this does not match the setting, an
alarm is generated.
Inherent to the MAIN input
Alarm generation and display re. Traffic
Program status control. If this does not match
the setting, an alarm is generated
Inherent to the MAIN input
Alarm generation and display re. Music/Speech
status control. If this does not match the setting,
an alarm is generated
Inherent to the MAIN input
Alarm generation and display re. Program
Service status control. If this does not match
the setting, an alarm is generated.
Inherent to the MAIN input
Alarm generation and display re. the presence
of traffic information (TMC).
Inherent to the MAIN input
Alarm generation and display re. the presence
of the Enhance Other Network control.
Inherent to the MAIN input
Alarm generation and display re. the presence
of the Alternative Frequencies List control.
Inherent to the MAIN input
Alarm and generation display re. quality of the
RDS service (expressed as a %)
Inherent to the FM input (Monitor-RF)
Alarm generation and display re. PI control. If
this does not match the setting, an alarm is
generated
Inherent to the FM input (Monitor-RF)
Alarm generation and display re. Program Type
control. If this does not match the setting, an
Inherent to the FM input (Monitor-RF)