XF40-Q2901Explosion-ProtectedTemperatureAlarmCamera
Aboutdetectors
Aboutdetectors
TemperatureDetection
Temperaturedetectionisusedtogenerateanalarmwheneverthetemperaturechangesaccordingtodenedconditions:
Thetemperaturerisesaboveaspeciedtemperature
Thetemperaturefallsbelowaspeciedtemperature
Thetemperatureincreasesaboveaspeciedrate
Temperaturedetectionissetbyconguringuptosixtemperaturedetectionzonesinthecameraview.Oncetemperaturedetection
zonesarecongured,theAxisproductcanbeconguredtoperformactionswhentemperaturechangesaredetected.Possibleactions
includedisplayofoverlaytextandstartrecording.Formoreinformation,seeHowtosetupactionrulesonpage34.
Note
Todetecttemperaturesabove150°C(302°F),theareaabovethistemperatureareamustbelargerthan3%oftheexposure
zone.Toresizetheexposurezone,seeAboutexposuresettingsonpage19.
SetupTemperatureDetectionZones
Tosetupatemperaturedetectionzonewithdetectionconditionsthatapplyforactionrules,followtheseinstructions:
BasicSettings
1.GotoDetectors>TemperatureDetection
2.ClickNewtocreateanewzoneandenteradescriptivename.
3.Adjustthezonesize(dragtheframe)andthezoneposition(clickonthetextatthetopanddragtothedesiredposition).
4.SelecttheDetectionTypeforthezone:
-Above(A):Triggersifthetemperaturerisesabovethelevel(C)thatyouhavesetintheDetectionTemperature
eld.Bydefault,maximumtemperatureinthezoneisusedasthebasefortemperaturedetection.