Specifications
-ReaderI/O:DCoutput:2x12VDCoutput,max486mA;2x2congurablesupervisedinputs/outputs(digital
input:0tomax30VDC;digitaloutput:0tomax30VDC,opendrainmax100mA)
-Readerdata:OSDP/RS485halfduplex,Wiegand
-Auxiliary:DCoutput:1x12VDCoutput,max200mA,4xcongurableinputs/outputs(digitalinput:0tomax
30VDC;digitaloutput:0tomax30VDC,opendrainmax100mA)
-Doorconnections:2x2supervisedinputsfordoormonitorsandREX(digitalinput:0tomax30VDC)
-External:2xcongurableinputs/outputsforauxiliaryequipment(digitalinput:0tomax30VDC;digital
output:0tomax30VDC,opendrainmax100mA)
Cablerequirements
-Wiresizeforconnectors:CSA:AWG28–16,CUL/UL:AWG30–14
-DCpowerandrelay:AWG18-16
-EthernetandPoE:STPCAT5eorhigher
-Readerdata(RS485):1twistedpairwithshield,qualiedforupto1000m(3281ft)
-Readerdata(Wiegand):Qualiedforupto150m(500ft)
-Readerpoweredbycontroller(RS485):AWG20-16,qualiedforupto200m(656ft)(Dependingonthe
reader’svoltageandcurrentinputrange.EvaluatedwithA4020-EandA4120-E.)
-Readerpoweredbycontroller(Wiegand):AWG20-16,qualiedforupto150m(500ft)(Dependingonthe
reader’svoltageandcurrentinputrange.)
-I/Osasinputs:Qualiedforupto200m(656ft)
LEDindicators
LED
Color
Indication
Green
Steadyforconnectiontoa100MBit/snetwork.Flashesfornetworkactivity.
Amber
Steadyforconnectiontoa10MBit/snetwork.Flashesfornetworkactivity.
Network
UnlitNonetworkconnection.
GreenSteadygreenfornormaloperation.
Amber
Steadyduringstartupandwhenrestoringsettings.
Status
Red
Slowashforfailedupgrade.
Green
Normaloperation.
Power
Amber
Flashesgreen/amberduringrmwareupgrade.
Green
Relayactive.
1
Relay
UnlitRelayinactive.
1.RelayisactivewhenCOMisconnectedtoNO.
Buttons
Controlbutton
Thecontrolbuttonisusedfor:
23

Other manuals for Axis A1210

Related product manuals