AXISA9188NetworkI/ORelayModule
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
Important
TheoutputcircuitsinthissectionareClass2powerlimited.
Important
ThetotalpowerfromallDCoutputsare12W(PoEType2Class4)or3.6W(PoEType2
Class3).
RelayConnector
4-pinrelayterminalblockfor:
0VREF
NO
COM
NC
FunctionPinNotes
Specications
0VREF
1
0VREF
NO
2
Forconnectingauxiliaryequipment.
COM
3
Forconnectingauxiliaryequipment.
NC
4
Forconnectingauxiliaryequipment.
0tomax30VAC/DC1A
WhenPoEpowered,
relayoutput
isonlyrated
12VAC/DC(1A)or
24VAC/DC(500mA).
WARNING
Maximumconnectedloadontherelayis30VAC/DC,1A