AXISCameraStationS1132Recorder
Troubleshooting
LifecycleControllerretrievestheselectedreportdataandexportsthereportletothespeciedlocation.Thiscan
takeafewminutes.
EnableIDRAC
YoucansetuptheIPaddressorusethedefaultiDRACIPaddress192.168.0.120tocongureinitialnetworksettings,including
settingupDHCPorthestaticIPforiDRAC.Bydefault,thededicatediDRACnetworkcardisdisabled.TheiDRACissharingthe
networkcardonLOM1(LANonMotherboard).Inthecaseofbladeservers,theiDRACnetworkinterfaceisdisabledbydefault.
TosetupiDRACIPusingiDRACsettingsutility:
1.Turnonthemanagedsystem.
2.PressF2duringPower-onSelf-test(POST).
3.IntheSystemSetupMainMenupage,clickiDRACSettings.
4.ClickNetwork.
5.EnableNIC.
6.Specifytheothernetworksettings.
7.ClickBack,Finish,andthenYes.Thenetworkinformationissavedandthesystemreboots.
YoucanopentheiDRACwebpagefromanysupportedbrowser.Thedefaultlogininformationis:
-Username:root
-Password:availableonthebackoftheinformationtag.
8.AfteryoucongureiDRACIPaddress,ensurethatyouchangethedefaultusernameandpasswordaftersettingupthe
iDRACIPaddress.
Note
Ifthereisanyaccessissue:
•TrytopingtheiDRACIPtocheckthatthenetworkcongurationhasbeenreplied.
•CheckwhichLOM(networkcard)hasbeenselectedintheiDRACnetworksettings.TheLOMcanbesharedwiththe
servernetworkcardsorusethededicatediDRACNIC's.
Troubleshootthepowersupplyunit
Note
Afterinstallingapowersupplyunit,allowseveralsecondsforthesystemtorecognizethepowersupplyunitanddetermineif
itthepowersupplyworksproperly.
1.Ensurethatnolooseconnectionsexist.Forexample,loosepowercables.
2.EnsurethatthepowersupplyhandleLEDindicatesthatthepowersupplyisworkingproperly.
3.Checkthestatusofthepowerindicatoronthepowersupplyunit.
-Ifthepowerindicatorisgreen,resetthepowersupplyunit.Ifthisdoesnotxtheissue,testthesystem
withagoodpowersupplyunit.
-Ifthepowerindicatorisamber,thisindicatesapowersupplyunitfaultcondition.Replacethepowersupplyunit
withagoodpowersupplyunitandchecktheindicatorstatus.
-Iftheissueisresolved,considerreplacingthepowersupplyunit.
27