AXISA1610NetworkDoorController
Specifications
Important
•Whenthereaderispoweredbythecontroller,thequaliedcablelengthisupto150m(500ft).
•Whenthereaderisnotpoweredbythecontroller,thequaliedcablelengthforreaderdataisupto150m(500ft)
ifthefollowingcablerequirementismet:AWG20-16.
Supervisedinputs
Tousesupervisedinputs,installendoflineresistorsaccordingtothediagrambelow.
iInput
ii
0VDC(-)
UL:SupervisedinputswerenotevaluatedbyULforburglaryuse.OnlydoormonitorandREXsupportsupervisionwithendof
lineresistors.
Note
Itisrecommendedtousetwistedandshieldedcables.Connectshieldingto0VDC.
Doorconnector
Two4-pinterminalblocksfordoormonitoringdevices(digitalinput).
Onlydoormonitorsupportssupervisionwithendoflineresistors.Iftheconnectionisinterrupted,analarmistriggered.Touse
supervisedinputs,installendoflineresistors.Usetheconnectiondiagramforsupervisedinputs.Seepage23.
FunctionPinNotes
Specications
DCground
1,3
0VDC
Input
2,4
Forcommunicatingwithdoormonitor.
DigitalinputorSupervisedinput—Connectto
pin1or3respectivelytoactivate,orleaveoating
(unconnected)todeactivate.
0tomax30VDC
Important
Thequaliedcablelengthisupto30m(98.4ft)ifthefollowingcablerequirementismet:AWG24.
Relayconnector
Two4-pinterminalblocksforformCrelaysthatcanbeused,forexample,tocontrolalockoraninterfacetoagate.