AXISA1610NetworkDoorController
Specifications
DigitalinputConnecttopin1or3toactivate,or
leaveoating(unconnected)todeactivate.
0tomax30VDC
Congurable(Input
orOutput)
2,4
DigitaloutputConnecttopin1or3toactivate,or
leaveoating(unconnected)todeactivate.Ifused
withaninductiveload,e.g.,arelay,connectadiode
inparallelwiththeload,toprotectagainstvoltage
transients.
0tomax30VDC,opendrain,
100mA
Powerconnector
2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheither
aratedoutputpowerlimitedto100Woraratedoutputcurrentlimitedto5A.
FunctionPinNotes
Specications
0VDC(-)
1
0VDC
DCinput
2
ForpoweringcontrollerwhennotusingPowerover
Ethernet.
Note:Thispincanonlybeusedaspowerin.
10.5–28VDC,max36W
UL:DCpowertobesuppliedbyaUL294,UL293orUL603listedpowersupply,dependingonapplication,withappropriateratings.
12Vbackuppowerinput
Forabackupsolutionusingabatterywithbuilt-incharger.12VDCinput.
UL:TheconnectorhasnotbeenevaluatedbyUL.
Important
Whenthebatteryinputisused,anexternal3Aslowblowfusemustbeconnectedinseries.
FunctionPinNotes
Specications
0VDC(-)
1
0VDC
Batteryinput
2
Forpoweringthedoorcontrollerwhenotherpower
sourcesareunavailable.
Note:Thispincanonlybeusedasbatterypowerin.
ForconnectiontoUPSonly.
11–13.7VDC,max36W
26