EasyManua.ls Logo

Bacharach MultiZone - Page 5

Bacharach MultiZone
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Multi-Zone Gas Monitors
P/N: 3015-5074 Rev 11 v
4.4.1. Functional Overview ....................................................................................................33
4.4.2. Responding to Alarms ..................................................................................................34
4.4.3. Alarm Detail Screen .....................................................................................................34
4.4.4. Acknowledging Alarms .................................................................................................35
4.4.5. Silencing an Alarm .......................................................................................................35
4.4.6. Clearing the Alarm Event Log .......................................................................................36
4.5. System Faults .........................................................................................................................36
4.5.1. Functional Overview ....................................................................................................36
4.5.2. Navigating to the Fault Screen ......................................................................................37
4.5.3. Critical Faults ..............................................................................................................37
4.5.4. Non Critical Faults .......................................................................................................38
4.5.5. Reset to Factory Default Settings..................................................................................38
4.5.6. Clearing System Faults ................................................................................................38
4.5.7. Viewing Fault Log ........................................................................................................39
4.5.8. Viewing Flow Log ........................................................................................................39
4.6. The Trend Screen....................................................................................................................40
4.6.1. Navigating to the Trend Screen ....................................................................................40
4.7. The Calibration Screen.............................................................................................................40
4.7.1. Overview.....................................................................................................................40
4.7.2. Navigating to the Calibration Screen .............................................................................41
4.7.3. Calibration Procedure (HGM and AGM Only).................................................................41
4.7.4. Adjusting Calibration Factor (HGM and AGM Only) ........................................................41
4.7.4. CO
2
Atmospheric Concentration ...................................................................................42
4.7.6. Programming New Gases (HGM Only)..........................................................................42
4.8. Zone Hold Mode........................................................................................................................43
4.9. The Diagnostic Screen .............................................................................................................44
4.9.1. Navigating to the Diagnostic Screen..............................................................................44
4.9.2. Diagnostic Screen Overview.........................................................................................45
SECTION 5. MAINTENANCE...........................................................................................................47
5.1. Replacement Parts Overview ...................................................................................................47
5.2. Replacement Parts and Optional Accessories............................................................................48
5.3. Troubleshooting.......................................................................................................................50
APPENDIX A. RECOMMENDED REFRIGERANT GAS ALARM SETTINGS .....................................53
APPENDIX B. RS-485 COMMUNICATIONS PROTOCOL ................................................................55
B.1. Overview.................................................................................................................................55
B.2. MODBUS RTU Protocol ...........................................................................................................55
B.3. MZ MODBUS RTU Operation ...................................................................................................55
B.3.1. Overview.....................................................................................................................55
B.3.2. Protocol Details ...........................................................................................................55
B.3.3. MZ Monitor Polling .......................................................................................................56
B.3.4. Network Topologies .....................................................................................................56
B.3.5. Key Comm Protocol Parameters ...................................................................................56
B.3.6. Summary of Registers..................................................................................................57
B.3.7. System Data Register 0x0010 (16 Dec) (R/W, 54 Bytes) ................................................58
B.3.8. Status Register 0x001 (17 Dec) (R/W, 10 Bytes)............................................................58
B.3.9. Fault Code Table .........................................................................................................59
B.3.10. Zone Data Register 0x12xx (R/W, 78 Bytes) ..................................................................59
B.3.11. Alarms and Alarm Acknowledge ...................................................................................60
B.3.12. Date Time Register 0x0015 (21 Dec) (R/W, 14 Bytes) ....................................................60
B.3.13. Sensor Data Register 0x0016h (22 Dec) (R, 82 Bytes) ...................................................61
B.3.14. Release Zone Hold Register 0x0017h (23 Dec) (W, 10 Bytes) ........................................61
B.3.15. Hold Zone Register 0x0018h (23 Dec) (W, 10 Bytes) .....................................................61
B.3.16. MZ Hold Mode .............................................................................................................61

Table of Contents

Related product manuals