Overview of Setup Functions
Setup Functions and Variables
1 Total
11 UNIT L, m
3
, kg, lb, GAL, USGAL, bbl, no unit
12 DECIMALS 0, 1, 2, 3 (Ref: displayed value)
13 K-FACTOR 0.000010…9,999,999 (see chart)
14 DECIMALS K-FACTOR 0…6
15 Multiplication factor x1, x10, x100, x1000, x10000
2 Flow Rate
21 UNIT mL, L, m
3
, mg, g, kg, ton, GAL, bbl, lb, cf, REV, no unit, scf, Nm
3
, NL, P,
MGAL
22 TIME UNIT sec, min, hour, day
23 DECIMALS 0, 1, 2, 3 (Ref: displayed value)
24 K-FACTOR 0.000010…9,999,999
25 DECIMALS K-FACTOR 0…6
26 CALCULATION per 1…255 pulses
27 CUT-OFF 0.1…999.9 secs
3 Display
31 FUNCTION total, flow rate
4 Power Management (Does Not Apply to This Unit)
5 Flowmeter
51 SIGNAL npn, npn_lp, reed, reed_lp, pnp, pnp_lp, act_8.1, act_12, act_24
6 Analog
61 OUTPUT disable, enable
62 4 mA 0000.000…9,999,999
63 20 mA 0000.000…9,999,999
64 CUT-OFF 0.0…9.9%
65 TUNE MIN, 4 mA 0…9,999
66 TUNE MAX, 20 mA 0…9,999
67 FILTER 00…99
7 Pulse
71 PULSE WIDTH 0…250
72 PULSE PER X,XXX,XXX quantity
8 Communication (Does Not Apply to This Unit)
9 Others
91 MODEL F100-P
92 TYPE ER-420LP / ER-420DC / ER-420AC
93 SOFTWARE VERSION __.__.__
94 SERIAL NO. xxxxxxx
95 PASS CODE 0000…9999
96 TAGNUMBER 0000000…9999999