HEATING SYSTEMS
12V FUSE REPLACEMENT
The fuse is in the electronics beneath the
connection cover.
Replace the unit’s fuse only with an identical
fuse.
Device fuse 10 A – low – (T 10 A)
230V FUSE REPLACEMENT
The fuse and the power supply lines must only
be replaced by an expert.
The unit must be disconnected from the mains
before opening the electronic housing lid.
The fuse is in the power electronics beneath
the electronic housing lid.
This fine fuse must always be replaced with a
fuse of the same type: T 10 A slow, interrupting
capacity H.
OVERHEATING PROTECTION 230V
The 230v heating facility has a mechanical
overheating switch. If the 12v power supply
is interrupted during operation or during the
after-run period for example, the temperature
within the unit could activate the overheating
protection.
To reset the overheating protection, allow
heater to cool, remove connection cover and
press red reset button.