5. OPERATION
5.1. THE APPLICATION OF THE JELLY QUICK
Operation
The instructions below deal with the application of the spray gun.
• Remove the spray gun from the holder.
• Mount the nozzle required (flat or round spray nozzle) to the spray gun. Unscrew
the screw cap on the front of the spray gun. Place the nozzle required in the screw
cap with the narrower diameter to the front and re-secure the screw cap.
Caution: Always place the plastic washer behind the stainless steel nozzle.
This is not necessary for plastic nozzles. (See picture)
How to clean the round spray nozzle.
- Spraying the product evenly:
Hold the spray gun approximately 10 cm/ 4” directly above the product.
Round spraying: Move the gun in circular movements above the product.
Flat spraying: Move the gun evenly backwards and forwards above the product.
- Return the spray gun to its holder.
Changing glaze packet/box
• Remove the quick coupling and valve cap from the empty bag in the box and
place it in the new or refilled packet.
When doing this it is not necessary to switch off the machine.
To guarantee good function of the electrical heated hoses, please observe the
following:
• Never cut the hose.
• Never pull on the hose (s) to move the machine.
• Never tightly bend hose (s).
• Never move the hose (s) over sharp objects.
• Place the spray gun (s) in the holder (s) when not in use.
5.2. SHUTTING DOWN THE GLAZE SPRAYER
- Switch off the machine when the work is completed.
- Disconnect the machine from the electricity supply.
- Spray the gun empty until the pressure has subsided.