20906 Higgins Court, * Torrance, CA 90501 * Tel. (310) 533-3939
CLEANING GUIDELINES
Before any period of inactivity of more than 24 hours, and after a max. of 40 operating
hours, the following cleaning procedure must be carried out:
With the machine turned on and warm (red light should be off)
Rinsing out pipe system
- Fill a bucket with lukewarm water at a maximum of 100F/40C.
- Remove nozzle from spray gun
- Place suction hose with quick coupling and valve cap in the water bucket. The
valve cap needs to click into the quick coupling or no water will go through.
- Spray water completely until bucket is empty.
- Install the clean nozzle (see below) back on the spray gun.
Cleaning the nozzle (as need basis)
• Unscrew the nut at the front of the spray gun. Take out the nozzle and rinse it in
hot water. For round nozzle (round hole in the nozzle instead of flat line), use a
screwdriver to remove the nozzle insert and rinse. Once clean, screw the insert in
place. Use the nut to secure the nozzle back in place.