BALDOR AIR COMPRESSOR
f、THE CONFIRMATION OF AIR CAPACITY
1. Calculate the air capacity according to the sum of average consumption
:air capacity
:
:sum of air compressor or workshop average consumption
: Consumption inequality (maximum) coefficient 1.2-1.4
: The leakage coefficient of connect pipeline. When the pipe length is less than 1 km, take
0.1; Shorter than 0.5 km, take 0.15; Longer than 2 km, take 0.2.
: using air equipments wearing consumption coefficient is 0.15 ~ 0.2
: Unforeseen consumption coefficient is 0.1.
2. Calculate the air capacity according to maximum consumption
hmKQQ /)1(max
3
321
'
22
:
sum of using air equipment or workshop average consumption
:
The coefficient during the same period (according to various industries, by empirical data, it can
also be determined with reference to the
value of the similar projects).
,
,
the same with the above