BALDOR AIR COMPRESSOR
30
Chapter Eight: Common Faults and Treatment
faults
reasons
treatment
the compressor
can not start
The fuse is burned.
check and replace it
owe phase or “start” button in bad contact
Check and replace it.
set exhaust pressure wrongly
re-set it
the motor overload protection trip/
damage
check & maintain the motor/
waiting for the motor cooling
AC contactor faults
check & handle & replace
air end faults
Check and moved the air
end.
compressor
can not set up
pressure
minimum pressure valve leak air
check & adjust
Inlet valve get stuck in the closed
position, and the small hole blocked.
check & adjust
electromagnetic valve does not work
check the electromagnetic
valve/circuit
the air filter core is seriously blocked
clean/replace the filter core