BALDOR AIR COMPRESSOR
can not no-load
or remain
pressure when
no-load or
safety valve
fault
inlet valve does not work well
check the inlet control valve
electromagnetic valve does not work
the oil-air filter core is blocked
safety valve adjustment value changes or has
fault
exhaust
capacity and
pressure is
lower than
normal
air filter core is blocked
clean/replace air filter core
Oil or air leakage in the system.
use capacity is larger than compressor
exhaust capacity
check the connection of the
devices
inlet valve does not work well
check the inlet control valve
electromagnetic valve does not work or leak
exhaust
pressure is
overpressure to
stopped
pressure transmitter fails in working or
there is abnormal interference signal
the exhaust
temperature is
too high or
over
temperature
protection
environment temperature is too high
improve the environment
ventilation and lower the
temperature
the oil cooler surface is too dirty
something wrong with the fan or fan motor
check and replace the fan
the oil filter is blocked
temperature control valve fault
check and replace the
temperature control valve