802.1x Per Port Setting interface
Misc Configuration
1. Quiet Period: Sets the period during which the port does not try to
acquire a supplicant.
2. TX Period: Sets the period that the port waits before retransmitting the
next EAPOL PDU during an authentication session.
3. Supplicant Timeout: Sets the period the switch waits for a supplicant
response to an EAP request.
4. Server Timeout: Set the period the switch waits for a server response
to an authentication request.
5. Max Requests: Sets the number of authentications that time-out
before authentication fails and the authentication session ends.
6. Reauth period: Set the period of time after which connected clients
must be re-authenticated.
7. Click
Apply
.