Run or Action Mode
Animation
Description
50/50 Color 1 is displayed on 50% of every segment and Color 2 is displayed on the other 50% of every segment at the defined color intensities
and segment shift
50/50 Rotate Color 1 is displayed on 50% of every segment and Color 2 is displayed on the other 50% of every segment while rotating at the defined
speed, color intensities, rotational direction, and segment shift
Chase Color 1 is displayed as a single spot against the background of Color 2 while rotating at the defined speed, color intensities, rotational
direction, and segment shift
Intensity Sweep Color 1 repeatedly increases and decreases intensity between 0% to 100% on every segment at defined speed and color intensity
Scroll Color 1 fills two segments and those segments move in one direction up or down against the background of Color 2 at the defined speed,
color intensities, and rotational direction
Bounce Color 1 fills two segments and those segments move up and down between the top and bottom of the tower against the background of Color
2 at the defined speed, color intensities, and rotational direction
Color Spectrum The tower light scrolls through the 14 predefined colors with a different color on each segment at the defined speed, Color 1 intensity, and
rotational direction
Advanced Mode—Use Advanced Mode to set the value range, thresholds, colors, intensities, flash speeds, and animation types for
PWM, PFM, Counter, and Timer control inputs.
Advanced Mode
Parameters
Description
Control Type
PWM (Pulse Width Modulation): Apply a square wave signal to the PWM/PFM Input and vary the duty cycle from 0 to 100%
to set value. The signal must use a constant frequency between 100 to 10,000 Hz.
PFM (Pulse Frequency Modulation): Apply a square wave signal to the PWM/PFM Input and vary the frequency from 100 to
10,000 Hz to set the value. The signal must use a constant duty cycle from 10 to 90%.
Counter: Apply a single pulse to the Counter Input to change the value by 1. Apply a single pulse to the Reset Input to set the value to
the starting value, if enabled. The pulse signal must last a minimum of 16 ms; the value changes on the leading edge.
Timer: Apply constant power to the tower to change the value by 1 every 1 second. Use a constant on or off signal on the Timer Run
Input to start and pause the timer, respectively, if enabled. Apply a pulse to the Reset Input to set the value to the starting value, if
enabled. The pulse signal must last a minimum of 16 ms; the value changes on the leading edge.
Subsegment Style If the value is a partial percentage of a segment, select if segment will be on steady or analog dimmed to the partial percentage
Start From
Top: The value decreases from the maximum value
Bottom: The value increases from the minimum value
Reset Input Apply a pulse signal to the Reset Input to set the value to the starting value, if enabled. The pulse signal must last a minimum of 16 ms.
Threshold Dominance
Dominant: All segments display the active threshold color
Non-Dominant: Segments display their defined threshold color
Threshold Type:
Background
A defined color and intensity is displayed on segments that are not active
Threshold Type: Base A defined animation state is displayed on segments that are not defined within a threshold
Threshold Type
≤: The animation state is displayed on the segments that are less than or equal to the defined threshold
≥: The animation state is displayed on the segments that are greater than or equal to the defined threshold
Disabled: The threshold is disabled
Global Parameters and
Advanced Settings
Description
Orientation
Standard: The tower base is down
Upside Down: The tower base is up
Background Color A defined color and intensity is displayed on segments that are not active
Animation Sync
On: Segment animations align when any input state changes
Off: Segment animations will not be synchronized
Auto Restart
On: The counter and timer will reset to the starting value after reaching the end value
Off: The counter and timer will stop at the ending value
Timer Run Input Use a constant on or off signal on the Timer Run Input to start and to pause the timer, respectively, if enabled
PFM/PWM Filter Level
Smooths the input signal by varying the sample size
Low: The sample size is short and changes to the input signal are more noticeable
High: The sample size is long and changes to the input signal are less noticeable
TL50 Pro Tower Light