8-pin/Wire Models
7
6
2
1
5
10–30 V dc
or
4
3
Audible
S2
S3
S1
S4
S5
8
S6
S7/A
S1 = Segment 1
S2 = Segment 2
S3 = Segment 3
S4 = Segment 4
S5 = Segment 5
S6 = Segment 6
S7 = Segment 7
A = Audible
5
6
7
1
8
2
3
4
Pin
Color Segment Mode Advanced Mode
7 blue Common Common (PNP) or 10–30 V DC
(NPN)
6 pink Segment 1 Reset Input
2 brown Segment 2 10–30 V DC (PNP) or Common
(NPN)
1 white Segment 3 PWM, PFM, Counter, or Timer input
5 gray Segment 4 N/A
4 yellow Segment 5 N/A
8 red Segment 6 N/A
3 green Segment 7/Audible N/A
Pro Editor Configuration for the TL50 Pro
Banner's Pro Editor software offers an easy way to configure Pro Series-enabled touch and indicator devices, allowing users full
control of device states. The easy-to-use configuration software provides a variety of tools and capabilities to solve a wide range of
applications. Pro Editor includes a preview mode that allows users to verify device performance before writing a configuration to a
device. Configure any Pro Series-enabled device using the free Pro Editor software, available for download at
www.bannerengineering.com/proeditor.
Segment Mode—Use Segment Mode to activate each segment and to control the input wire, color, animation, intensity, and speed.
In Segment Mode, enable the Action Input to switch between Segment Mode and Run Mode (all segments) animations depending
on wiring. The combination of the Action Input and the Segment input controls all tower light segments at once.
Segment Mode
Animation
Description
Off Segment is off
Steady Color 1 is on at defined intensity
Flash Color 1 flashes at defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random)
Two Color Flash Color 1 and Color 2 flash alternately at defined speed, color intensities, and pattern (normal, strobe, three pulse, SOS, or random)
50/50 Color 1 is displayed on 50% of the segment and Color 2 is displayed on the other 50% of the segment at the defined color intensities
50/50 Rotate Color 1 is displayed on 50% of the segment and Color 2 is displayed on the other 50% of the segment while rotating at the defined speed,
color intensities, and rotational direction
Chase Color 1 is displayed as a single spot against the background of Color 2 while rotating at the defined speed, color intensities, and rotational
direction
Intensity Sweep Color 1 repeatedly increases and decreases intensity between 0% to 100% at defined speed and color intensity
Run Mode—Use the TL50 Pro's Run Mode to control the entire tower light and to control the input wire, color, animation, intensity,
and speed. Run Mode with a larger assigned run number overrides the lower assigned run numbers.
Run or Action Mode
Animation
Description
Off All tower light segments are off
Steady Color 1 is solid on for every tower light segment at defined intensity
Flash Color 1 flashes on every tower light segment at defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random)
Two Color Flash Color 1 and Color 2 flash alternately on every segment at defined speed, color intensities, and pattern (normal, strobe, three pulse, SOS, or
random)
TL50 Pro Tower Light
P/N 209142 Rev. D www.bannerengineering.com - Tel: + 1 888 373 6767 3