RS-232 command of Fans Control statement as below:
Op fan1~ fan12 = x , where x is the value about the fan speed, it can be setting
Op fan1~fan12 ? , it can be get fan speed
Op fan.all ? , it can be get all the fan speed.
op prerr , check last error code
op chevi = 0 , it can be set fan speed without check environment.
Ex.
Op fan5 = 2500
OP FAN5 = 2500 <- ACK
Ex.
Op fan5 ?
OP FAN5 = 2500
Ex.
Op fan.all ?
OP FAN1 = 1000 <-ACK
.
.
.
OP FAN12=2000
Ex. Use command to check last error code
op prerr
1. 10 <-ACK last
2. 5 <-ACK last sec