31
reads,”rAtE.”
9. Press the UP or DOWN button to select
a value in ramp units (seconds, minutes
or hours; set in the “rmP.U” parameter).
rmP.t
To ramp to a specified temperature at a set
time:
1. Press the PAGE button until you reach
the program list (ProG LiSt).
2. Press the SCROLL button until display
reads, “tYPE.”
3. Press the UP or DOWN button until dis-
play reads, “rmP.t.”
4. Press the SCROLL button until display
reads, “tGt.”
5. Press the UP or DOWN button to set a
target setpoint.
6. Press the SCROLL button until display
reads, “dur.”
7. Press the UP or DOWN button to select
a time in ramp units (seconds, minutes
or hours; set in the “rmP.U” parameter.
dwEll
To maintain a constant temperature for a speci-
fied time:
1. Press the PAGE button until you reach
the program list (ProG LiSt).
2. Press the SCROLL button until display
reads, “tYPE.”
3. Press the UP or DOWN button until dis-
play reads, “dwEll.”
8 S
EGMENT & 4
X16 SEGMENT
PROGRAMMABLE MODELS W/OTP