Upper Threshold Moisture Sensor-Based Watering
6. Press the
button to highlight the Greater Than Limit field, and then press the OK button. A
checkmark displays next to the Greater Than Limit option.
7. Review the setting in the Stop field, and then perform one of the following:
If At End of Cycle displays in the field, continue to step 8.
If Immediately displays in the field, press the + or button to change the setting to At End of
Cycle. Continue to step 8.
8. Press the
button to highlight the Calibration field.
If the calibration has not been enabled, the Start option displays on the right side of the screen.
To start the calibration, highlight the Start option, and then press the OK button.
If the calibration has been enabled, the Stop option displays on the right side of the screen. To
stop the calibration, highlight the Stop option, and then press the OK button.
9. Set the controller to run by pressing the RUN button.
After you enable the calibration, the process either starts immediately or at the next day and time
start. The controller adds 50% to the runtime of each zone in the program that’s being calibrated.
This additional runtime should water the landscape up to Saturation level. When the program is
finished, the controller waits 24 hours for the landscape to dry to field capacity, and then it takes
the calibration reading. That value is automatically entered into the Limit field.
After the calibration cycle runs one time, it is disabled in the controller.
Step 8 – Setting the Controller to Run
When you have finished making changes, press the RUN button.
Baseline Support: 866-294-5847 9 www.baselinesystems.com