Upper Threshold Moisture Sensor-Based Watering
Step 4 Assign the biSensor Zones to a Program
Put all zones that you want to water with the upper threshold strategy into one program by giving them
runtimes.
1. Press the Program Setup button. The Program Setup menu displays.
2. If the program that you are setting up to water based on biSensor readings displays in the upper-left
corner of the screen, continue to step 3. Otherwise, press the PRG button until the program that
you want to modify displays in the upper-left corner of the screen.
Note: To move backwards in the list of programs, press and hold the PRG button, and then press the
button repeatedly.
3. The Zone Runtimes option should be highlighted. If it is not highlighted, press the
or
button to
highlight it, and then press the OK button. The Zone Runtimes screen displays. Zones are identified
with a sequential number and by the serial number of the attached biCoder.
Note: Make sure the runtime is sufficient to get through the longest day interval during the hottest
time of the year (typically ¾ inch of water).
4. Notice that the minutes placeholder in the Zone 1 field is
highlighted.
To move to the hour placeholder, press the
button.
To move to the seconds placeholder, press the
button.
To change the time, press the + or button.
Note: To rapidly increase or decrease the value, press and hold the + button or the button.
To move to a different zone, press the
or
button.
Step 5 Setting Up the Day & Time Start Condition for the Program
In the BaseStation 1000, a program is not active until you select a start condition for it. When you are
using an upper threshold watering strategy, the program associated with the moisture sensor must have
a day and time start condition.
1. Press the Program Setup button. The Program Setup menu displays.
2. If the program that you are setting up to water based on biSensor readings displays in the upper-left
corner of the screen, continue to step 3. Otherwise, press the PRG button until the program that
you want to modify displays in the upper-left corner of the screen.
Note: To move backwards in the list of programs, press and hold the PRG button, and then press the
button repeatedly.
3. Press the
button to highlight the Setup Prg. Start option, and then press the OK button. The Setup
Prg. Start screen displays the list of start conditions.
Note: If you want the controller to display a message whenever a program starts, refer to Enabling
Start, Pause, and Stop Messages in the BaseStation 1000 User Manual.
Baseline Support: 866-294-5847 4 www.baselinesystems.com