Configuring the Camera
4-14 BASLER A202
k
DRAFT
4.2.4.5 Digital Shift
Purpose: To enable or disable digital shift. See Section 3.6 for an explanation of digital shift.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0xA5 1 1 -
Response: Cmd-ID R/W-Flag Data Length Data
0xA5 0 1 1 Byte
Write Command: Cmd-ID R/W-Flag Data Length Data
0xA5 0 1 1 Byte
Response: None
Data Format: Byte 1 An ID that specifies the digital shift status
(see the table below).
ID Digital Shift
0x00 No digital shift
0x01 Digital shift once (multiples output 2X)
0x02 Digital shift twice (multiples output 4X)
L
See Section 3.6.3 for precautions that you must consider when using digital shift.