Installation Guide
14 Basler IP Camera
If camera power will be supplied via the terminal connector:
1. Make sure that your power supply meets the requirements stated in
Table 2 on page 6.
2. Locate the two output wires on the power supply.
The positive wire will typically be marked with a white stripe, a colored
stripe, or some similar type of marking (see Figure 6).
If you are unsure which output wire is positive, check the output from the
supply with a voltmeter and mark the positive wire now.
3. Unplug or switch off the power supply.
4. Make sure that the output wires on the power supply have the following
characteristics:
A minimum cross section of 0.14 mm
2
(AWG 25) and a maximum cross
section of 0.5 mm
2
(AWG 20).
8 mm (5/16") of insulation has been stripped from the end of each output
wire.
If the output wires are stranded rather than solid, they must have an
8 mm (5/16") long ferrule (end terminal) applied to the end of each wire
as shown in Figure 6.
Fig. 6: Ferrules Applied to Stranded Wire
Ferrules (end terminals)
Positive Wire Marked
Ground Wire