INSTALLATION NOTES
1. Before installing this oven it is necessary for the rear
panel of the cabinet be removed.
2. A 85 - 90mm ventilation gap must be allowed between the
appliance support shelf and the rear wall and a 35 - 40mm gap
between the rear of the appliance and the rear wall.
3. A minimum ventilation area of 80cm² must be allowed below
the appliance at plinth level.
4. If the tall housing is fitted flush with the kitchen ceiling, a
20cm² ventilation cut-out must be provided in the front of the
housing at the top (not shown in drawing).
5. The oven is fixed into the housing with two screws through
each side frame and side rail.
18