GENERAL INJECTORS TABLE
Power (in watts) Kind of gas Nozzle
mm/100
Burners
Max. Min.
Natural 135
115
97
72
Wok
Rapid
Semi-rapid
Auxiliary
3500
3000
1750
1000
1700
700
400
350
L.P.G.
Butane
Propane
95
85
65
50
Wok
Rapid
Semi-rapid
Auxiliary
3500
3000
1750
1000
1700
700
400
350
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.
o Switch the burner on
and set the knob at the
minimum position.
o Remove the knob from
the tap and place a
small bladed
screwdriver in the
centre of the tap shaft.
o Unscrew the adjusting screw, in order to increase the gas flow or
tighten the adjusting screw to decrease the gas flow.
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
21