Messages and Warnings Commissioning
BUG 3/2/20 Basic Feed Unit 47
Baumüller Nürnberg GmbH 5.96064.02
Ballast
Ballast monitoring supervises the switching frequency of the ballast transistor. If the maximum time
exceeeds the internally set time, the system issues a message and cancels ready-for-use.
This message is issued in the following cases:
if the braking power is too high
if the continuous power of the ballast resistor is too high
if the short-time loading is longer than two seconds
if the intermediate circuit voltage due to the mains overvoltage is greater than 375 V
Controller Supply
Controller supply monitoring supervises the internal switching power supply for overloading and
brief short-circuits. If one of these errors occurs, the system generates a message and cancels
ready-for-use.
Temperature
Overtemperature monitoring supervises the temperature of the heatsink. If this temperature ex-
ceeds an internally set limit value, the system issues a message and cancels ready-for-use.
This message is issued in the following cases:
if the input rectifier is overloaded
if the fan is blocked
if the ambient temperature is too high
System error
If the system issues one of the messages listed above, it is stored and displayed as the System er-
ror group message.
The system cancels ready-for-use and reports it to the connected servo units.
NOTE
You cannot clear messages whose disturbances are still pending.