29
USER Section (en)
7651556.01 (1-01/16)
154
Delivery/return probe control test Call the Authorised Service Centre.
160
Fan fault Call the Authorised Service Centre.
178
Intervention of safety thermostat for excess temperature in
ORZWHPSHUDWXUHV\VWHP
Call the Authorised Service Centre.
270
Overheating exchanger Call the Authorised Service Centre.
317 162
Call the Authorised Service Centre. Call the Authorised Service Centre.
321 163
Call the Authorised Service Centre. Call the Authorised Service Centre.
384 164
3DUDVLWHÀDPHLQWHUQDOHUURU
3UHVVDQGKROGGRZQ
for at least 2 seconds.
385 165
,QSXWYROWDJHWRRORZ
Automatic reset at voltages in excess of 175V. If this fault
persists, call the Authorised Service Centre.
431
Exchanger sensor faulty Call the Authorised Service Centre.
,QWKHHYHQWRIDIDXOWWKHGLVSOD\EDFNOLJKWLQJLQGLFDWHVWKHHUURUFRGHUHVHWDWWHPSWVFDQEHSHUIRUPHGDIWHUZKLFKWKH
ERLOHUVKXWVGRZQ:DLWPLQXWHVEHIRUHDWWHPSWLQJWRUHVHWWKHERLOHUDJDLQ
5. BOILER INFORMATION MENU
3UHVVDQGKROGGRZQ for at least 1 second, to display the information indicated in the table. Press to exit.
DESCRIPTION DESCRIPTION
00 Secondary fault internal code 06 +HDWLQJUHWXUQWHPSHUDWXUH&
01 +HDWLQJVXSSO\WHPSHUDWXUH& 07 )OXHVHQVRUWHPSHUDWXUH&
02 2XWGRRUWHPSHUDWXUH& 08 3ULPDU\H[FKDQJHUWHPSHUDWXUH&
03 Indirect tank DHW temperature (boiler CH only) 09 - 13 Manufacturer information
04
'RPHVWLFKRWZDWHUWHPSHUDWXUH
ERLOHUZLWKSODWHH[FKDQJHU
14 ,GHQWL¿FDWLRQ2SHQ7KHUPFRPPXQLFDWLRQ
05
- - -
15 - 18 Manufacturer information
6. SWITCHING OFF THE BOILER
7RWXUQRIIWKHERLOHUGLVFRQQHFWWKHHOHFWULFSRZHUVXSSO\XVLQJWKHWZRSROHVZLWFK,QWKH³2II´RSHUDWLQJPRGH the boiler stays
RIIEXWWKHHOHFWULFDOFLUFXLWVUHPDLQSRZHUHGDQGWKHDQWLIUHH]HIXQFWLRQUHPDLQVDFWLYH
7. FILLING THE SYSTEM
5HJXODUO\FKHFNWKDWWKHSUHVVXUHGLVSOD\HGRQWKHSUHVVXUHJDXJHBLVEDU
ZLWKWKHERLOHUFROG,IWKHSUHVVXUHLVWRRORZWXUQWDSAWR¿OOWKHERLOHU¿JXUHWR
side).
7DNH VSHFLDO FDUH ZKHQ ¿OOLQJ WKH KHDWLQJ V\VWHP ,Q SDUWLFXODU RSHQ DQ\
WKHUPRVWDWYDOYHVLQWKHV\VWHPHQVXUHWKHZDWHUHQWHUVVORZO\LQRUGHUWR
prevent the formation of air inside the primary circuit until operating pressure
is reached. Lastly, vent any radiators in the system. BAXI declines all liability for
damage deriving from the presence of air bubbles in the primary exchanger due to the
incorrect or imprecise observance of the above.
7KHERLOHULV¿WWHGZLWKDK\GUDXOLFSUHVVXUHJDXJHZKLFKSUHYHQWVWKHERLOHU
IURPZRUNLQJLIWKHUHLVQRZDWHU
,ISUHVVXUHGURSVRFFXUIUHTXHQWO\KDYHWKHERLOHUFKHFNHGE\WKH$87+25,6('7(&+1,&$/6(59,&(&(175(
8. ROUTINE MAINTENANCE INSTRUCTIONS
7RNHHSWKHERLOHUHI¿FLHQWDQGVDIHKDYHLWFKHFNHGE\WKH$XWKRULVHG6HUYLFH&HQWUHDWWKHHQGRIHYHU\RSHUDWLQJSHULRG
Careful servicing ensures economical operation of the system.