7110102.03 (1-06/13) 44
INSTALLER Section (en)
20. TECHNICAL SPECIFICATIONS
Model: ECO COMPACT 1.14 F 14 F 18 F 1.24 F 24 F
Category -
II2H3P
Gas used - G20 - G31
Rated heat input for DHW circuit. kW - 19.4 19.4 - 25.8
Rated heat input for heating circuit. kW 15.4 15.4 19.4 25.8 25.8
Reduced heat input kW 10.6 10.6 10.6 10.6 10.6
Rated heat output for DHW circuit kW - 18 18 - 24
Rated heat output for heating circuit kW 14 14 18 24 24
Heat input adjusted in heating kW 14 14 18 24 18
Reduced heat output kW 9.3 9.3 9.3 9.3 9.3
Rated efciency % 90.8 90.8 92.8 93.1 93.1
Efciency 30% Pn % 90.2 90.2 90.2 90.5 90.5
DHW / heating circuit max. water pressure bar 8 / 3
Expansion vessel capacity l 8
Expansion vessel minimum pressure bar 0.5
DHW min. dynamic water pressure bar 0.15
Minimum DHW ow I/min - 2.0 2.0 - 2.0
Production of DHW with ΔT =25 °C I/min - 10.3 10.3 - 13.7
Production of DHW with Δ T =35 °C I/min - 7.4 7.4 - 9.8
Specic ow “D” (EN 625) I/min - 8.6 8.6 - 11
Temperature range in heating system °C 30/85
Temperature range in DHW circuit °C 35/60
Fumes typology - C12 - C32 - C42 - C52 - C82 - B22
Coaxial ue duct diameter mm 60/100
Diameter of separate outlets mm 80/80
Max . ue mass ow rate kg/s
0.013 0.014 0.014 0.015 0.015
Min. ue mass ow rate kg/s 0.013 0.013 0.013 0.015 0.015
Maximum temperature of fumes °C 125 128 128 140 140
Minimum temperature of fumes °C 102 102 102 104 104
NOx 3 Class (EN 297 - EN 483) mg/kWh 133 133 128.7 132.6 132.6
Natural gas supply pressure 2H mbar 20
Propane gas supply pressure 3P mbar 37
Power supply voltage V 230
Power supply frequency Hz 50
Rated power supply W 110
Net weight kg 28 29 29 28 29
Dimensions (height/width/depth) mm 700/400/298
Humidity protection level (EN 60529) - IPX5D
CE Certicate 0085CN0144
CONSUMPTION AT HEAT INPUT Qmax and Qmin
Qmax (G20) – 2H m
3
/h 1.63 2.05 2.05 2.73 2.73
Qmin (G20) – 2H m
3
/h 1.12 1.12 1.12 1.12 1.12
Qmax (G31) – 3P kg/h 1.2 1.51 1.51 2.00 2.00
Qmin (G31) – 3P kg/h 0.82 0.82 0.82 0.82 0.82