16.0 Electrical
© Baxi Heating UK Ltd 2013
- brown
- black
- blue
- white
br
bk
b
w
- green
- green / yellow
- red
g
g/y
r
Control PCB
X2 X3
X501
1212 3
3
44
5
5
6789
X1
12
Central Heating
NTC Sensor
Fan
Gas Valve
Overheat Stat
Flame
Sensing
Electrode
Pump
Flue Sensor
X401
r
r
b
b
b
b
b
br
bk
g
b
br
g/y
b
br
b
br
br
b
b
b
br
br
br
b
b
br
r
bk
r
bk
Spark
Generator
Ignition
Electrode
910 8 7 6
54321
N
L
w
g
1
4
2
5
3
1
2
a
b
Link
bk
b
g/y
br
Mains Input Cable
br
b
X9
Return Heating
Temperature Sensor
X400
g
g
b
b
Water Pressure
Switch
9876
54321
b
w
16.1 Illustrated Wiring Diagram

Other manuals for Baxi Megaflo System HE A Range

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baxi Megaflo System HE A Range and is the answer not in the manual?

Baxi Megaflo System HE A Range Specifications

General IconGeneral
BrandBaxi
ModelMegaflo System HE A Range
CategoryBoiler
LanguageEnglish

Related product manuals