Baxi MULTIFIT Flue Systems - Plume Displacement Kit (PDK) Clearance Requirements; PDK Outlet and Inlet Height Requirements; PDK Outlet Angle and Terminal Guard

Baxi MULTIFIT Flue Systems
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
page 13
© Baxi Heating UK Ltd 2011
Air Inlet at Bottom
45°
45°
Outlet must be at
least 45° from
wall face
500mm Min.
FITTING PLUME DISPLACEMENT KIT
200mm Min.
500mm Min.
2 metres Min.
The outlet of the PDK
MUST be at least 2
metres above ground or
balcony level. If
necessary additional
60Ø extensions should
be used to achieve this.
The inlet of the PDK
MUST be at least
300mm above ground
or balcony level or any
projection or ledge. A
guard must be fitted
where the inlet is below
2 metres.
300mm Min.
Terminal Guard
Part No 720644601