3- Power supply
HEAT METER can be fitted ER34615 battery with operating time of 10 years at 1 read per day.
Type
Lithium Battery
Model No.
ER34615
Size
D Size
Rated capacity
19000mAh
Rated voltage
3.6V
Max recommended
continuous operating current
230mA
Max pulse current
400mA
Reference weight
100g
Max dimension
33.1×61.5mm
Operating temperature
-60°C+85°C
4- Interface & Communication
RF Communication
Automatic meter reading with RF (Radio Frequency)
Center Frequency : 868 Mhz (Works in AT approved ISM/SRD Frequency)
Protocol: Wireless Mbus (wM-BUS)
Modulation : GFSK
Transmitter output power : Adjustable up to +14dB
Communication Speed : 1.2-250 kbps
Communication Type : Bidirectional
Real time clock (IEC 61038 approved)
LoRa Communication(Optional)
Automatic meter reading with LoRa (Long Range RF)
Center Frequency : 868 Mhz (Works in AT approved ISM/SRD Frequency)
Protocol: LoRaWAN
Modulation : LoRa