Do you have a question about the BD Alaris neXus CC and is the answer not in the manual?
Device Type | Infusion Pump |
---|---|
Model | Alaris neXus CC |
Screen Type | Color Touchscreen |
Manufacturer | Becton, Dickinson and Company (BD) |
Battery Type | Rechargeable Lithium-ion |
Battery Life | Up to 8 hours |
Data Export | USB, Wireless |
Infusion Modes | Continuous, PCA, Intermittent |
Connectivity | Ethernet, USB, Wireless |
Explains formatting conventions like bold, italics, and single quotes used in the manual.
Introduces the BD Alaris™™ neXus CC Syringe Pump and its basic functionality.
Defines the primary use of the syringe pumps in healthcare settings for fluid delivery.
Lists the primary and secondary users of the BD Alaris™™ neXus CC Syringe Pump.
Specifies the types of fluids and conditions for which the pump is intended.
Lists the clinically acceptable routes for therapy delivery using the syringe pumps.
Lists compatible hardware and software for the BD Alaris™™ neXus CC Syringe Pump.
Explains the function of each button and control on the pump.
Describes the meaning of various indicator lights and symbols on the pump.
Details the key information displayed on the pump's main screen.
Explains the meaning of common icons displayed on the pump's screen.
Identifies and explains the meaning of various symbols and labels found on the pump.
Provides step-by-step instructions for the initial setup of the syringe pump.
Explains how to select the desired language for the pump interface.
Details how to connect the pump to a power source.
Outlines the process for configuring the pump's Wi-Fi connectivity.
Instructs on how to install the pump using the pole clamp.
Describes how to mount the pump on a workstation or equipment rail.
Explains how to use the optional lock box for syringe security.
Details the steps for closing the optional lock box after use.
Provides precautions related to the use of syringes and extension sets.
Specifies suitable environments and precautions for pump operation.
Highlights critical hazards associated with the pump's use and maintenance.
Discusses EMC requirements and potential interference issues.
Provides detailed instructions on how to load a syringe into the pump.
Details the critical steps for securely loading and confirming the syringe.
Guides the user through the step-by-step process of operating the syringe pump.
Describes how to administer a bolus dose of medication or fluid.
Explains the manual bolus delivery method, noting it's not best clinical practice.
Details the procedure for purging the extension set.
Explains how to set a specific volume to be infused and the end-of-infusion rate.
Describes how to clear the infused volume data.
Explains the rate lock feature and its implications for pump operation.
Describes how to adjust the infusion rate while infusing or on hold.
Guides on how to review currently selected dosing information.
Explains how to set a VTBI and delivery time, calculating the rate.
Details how to review the 24-hour log of volume infused.
Explains how to review the pump's event log.
Guides on how to change the infusion setup.
Provides information on viewing wireless network connection status.
Explains how to enable or disable wireless communication for the pump.
Details how the pump monitors pressure and the features related to it.
Explains the automatic adjustment of the pressure occlusion limit.
Guides on checking and adjusting pressure levels when a pressure disc is fitted.
Guides on checking and adjusting pressure levels when no pressure disc is fitted.
Lists and explains the original alarm conditions and their troubleshooting.
Explains the visual and audio indicators for different alarm priorities.
Lists and explains the third edition alarm conditions and their troubleshooting.
Lists and explains prompts indicated by audible alarms and messages.
Lists various options that can be configured via the pump or software.
Explains how to select and configure alarm tones and presets.
Details settings configurable via the BD Alaris™™ neXus Editor Software.
Lists settings for configuring the data set used by the pump.
Outlines general pump settings that can be configured.
Lists additional general configurations specific to syringe pumps.
Explains the various dose rate units available for Guardrails™™ settings.
Details drug parameters configurable via the BD Alaris™™ neXus Editor Software.
Explains how to create and manage the syringe library for pump profiles.
Provides a list of syringes that are calibrated and approved for use with the pump.
Details specifications for the Alaris™™ Gateway Workstation.
Provides specifications for the BD Alaris™™ MRI Capsule.
Lists compatible extension sets for use with the pump.
Details standard extension sets compatible with the pump.
Lists specific TPN (Total Parenteral Nutrition) sets.
Lists light-protected extension sets.
Lists extension sets suitable for NICU (Neonatal Intensive Care Unit) use.
Lists low sorbing extension sets.
Outlines routine procedures for keeping the pump in good operating condition.
Explains how the internal battery operates and its maintenance.
Provides instructions on how to clean and store the pump.
Offers guidance on the proper disposal of the pump and its components.
Lists the general specifications of the syringe pump.
Details infusion rate capabilities and increments.
Outlines the specifications for bolus infusion rates and volumes.
Presents data on the accuracy of bolus volume delivery with and without a pressure disc.
Indicates the highest alarm level for pumping pressure.
Details the specifications for the purge function.
Provides occlusion accuracy data with and without a pressure disc.
Details system accuracy at different rates and temperatures.
Details the specifications for the rechargeable battery.
Outlines the specifications for the pump's wireless module.
Lists various alarm conditions that the pump can detect.
Details the acceptable environmental operating and storage conditions.
Confirms compliance with electrical and mechanical safety standards.
Explains how occlusion pressure limits are set and their effect on alarming.
Details the specifications for IrDA, RS232, and Nurse call interfaces.
Provides connection data and pinouts for RS232 and Nurse call.
Explains trumpet and start-up curves used to assess performance.
Details available spare parts and accessories for the pump.
Lists compatible software for the pump.
Lists contact details (telephone, email) for customer service by country.