Do you have a question about the BD Alaris neXus GPneXus1 and is the answer not in the manual?
Device Type | Infusion Pump |
---|---|
Volume to be Infused (VTBI) | 0.1 to 9999 ml |
Power Supply | 100-240 VAC, 50/60 Hz |
Model | GPneXus1 |
Flow Rate Accuracy | ±5% |
Occlusion Pressure Settings | Low, Medium, High |
Operating Modes | Continuous, Intermittent |
Alarms | Air-in-line, Occlusion, Low battery, System error |
Battery Type | Lithium Ion |
Explains formatting conventions like bold, italics, and symbols used in the manual.
Introduces the pump, its purpose, target users, and clinical benefits.
Details usage conditions, indications, contraindications, and compatibility.
Describes the pump's physical features, controls, indicators, and screen elements.
Explains screen icons and labelling symbols used on the pump.
Guides through initial pump setup, power, Wi-Fi configuration, and default data set.
Covers pole clamp, workstation mounting, safety clamp, and operating precautions.
Discusses operating environment, alarms, hazards, earth conductor, and EMC.
Provides step-by-step instructions for loading and priming the infusion set.
Explains flow sensor usage and the process of starting an infusion.
Details procedures for changing the infusion set and fluid container.
Details how to set up drugs, dosing units, and rates using the pump's options.
Explains setting VTBI, KVO rate, clearing volume, and priming procedures.
Describes bolus delivery modes and how to adjust the infusion rate while operating.
Covers rate lock functionality and adjusting existing dosing or protocol infusions.
Explains primary/secondary setup, setting VTBI over time, and managing event logs.
Details profile filtering, standby mode, network status, and wireless connection.
Explains secondary infusions and instructions for the SmartSite™ Needle-Free System.
Details high-priority alarms, their causes, and recommended actions.
Explains medium and low priority alarms, their indicators, and resolution steps.
Lists prompts and advisories, their causes, and required user actions.
Describes configurable options, alarm tone settings, and additional settings.
Details pump configuration settings managed via the BD Alaris™ neXus Editor Software.
Explains drug parameters and unit display configurations managed via the Editor Software.
Provides specifications and details for the Alaris™ Gateway Workstation.
Lists and describes various standard, TPN, and specialized infusion sets.
Outlines regular cleaning, inspection, and battery management procedures.
Provides detailed instructions for cleaning the pump, door, flow sensor, and storage.
Details electrical, mechanical, safety, and environmental specifications of the pump.
Explains specifications for Wi-Fi, IrDA, RS232, and Nursecall interfaces.
Details system accuracy, occlusion alarm limits, and bolus administration parameters.
Presents performance curves illustrating pump accuracy and flow onset delay.
Lists available spare parts for the pump with part numbers and descriptions.
Lists compatible software applications for the pump, including part numbers.
Provides a record of document revisions, dates, software versions, and descriptions.
Lists contact details (telephone, email) for customer service by country.