What to do if an unexpected plate lid was detected in the pick area of BD Laboratory Equipment?
- MMichael WhiteheadSep 6, 2025
If an unexpected plate lid was detected in the pick area, remove the plate lid.
What to do if an unexpected plate lid was detected in the pick area of BD Laboratory Equipment?
If an unexpected plate lid was detected in the pick area, remove the plate lid.
What to do if there are insufficient reagents available in BD Kiestra IdentifA Laboratory Equipment?
If you encounter insufficient reagents, check the levels of matrix solution, formic acid solution, and BTS solution.
What to do if a waste bin is full in BD Kiestra IdentifA?
If a waste bin is full, empty it.
What to do if the plate outfeed is full on BD Kiestra IdentifA?
If the plate outfeed is full, remove processed plates from the plate outfeed.
What to do if no liquid is found in the target cuvette in BD Kiestra IdentifA?
If no liquid is found in the target cuvette, select 'Error Resolved', then select 'Start'.
What to do if more than one daily nephelometer cuvette array is available in BD Kiestra IdentifA Laboratory Equipment?
If more than one daily nephelometer cuvette array is available, please remove one of the two cuvette arrays.
What to do if an error occurred during the transport of a cuvette array in BD Kiestra IdentifA Laboratory Equipment?
If an error occurred during the transport of a cuvette array, check the cuvette array drawers and elevators to recover the fallen cuvette.
What to do if no free slots are available for a processed cuvette array in BD Kiestra IdentifA Laboratory Equipment?
If there are no free slots available for a processed cuvette array, remove ready or empty cuvettes from the right cuvette drawer.
What to do if a plate doesn't arrive at a stopper in BD Laboratory Equipment?
If a plate did not arrive within the expected time at a stopper, remove the plate and check for obstructions.
What to do if a plate doesn't arrive at the stacker position in BD Kiestra IdentifA Laboratory Equipment?
If a plate did not arrive within the expected time at a stacker position, remove the plate and check for obstructions.
Brand | BD |
---|---|
Model | Kiestra IdentifA |
Category | Laboratory Equipment |
Language | English |
Defines text formatting like bold and italics used in the manual for clarity.
Explains how safety messages (NOTE, CAUTION, WARNING) are presented and their meanings.
Lists and explains symbols used for safety, compliance, and device identification within the manual.
Clarifies that patient data shown is illustrative and not actual clinical information.
Describes the BD Kiestra™ IdentifA module's purpose for specimen preparation and organism identification.
Details the IdentifA module, user interface, and functional areas of the system.
Explains the IdentifA module's touchscreen interface for workflow actions and data entry.
Identifies the main areas of the IdentifA module for colony picking and suspension preparation.
Outlines crucial safety guidelines, operational limitations, and potential hazards of using the device.
Guides users on how to modify system settings for audible alerts, checks, and wait times.
Details how to configure the audible buzzer for system notifications and errors.
Specifies the time for the daily nephelometer check after module startup.
Specifies the time the system waits for cuvette arrays before proceeding with target spotting.
Defines the time the system waits before finishing target spotting if no new specimens arrive.
Details the steps for powering on the IdentifA module and initial system checks.
Explains how to log in to access basic and advanced functions of the IdentifA module.
Guides users on how to begin routine specimen processing after startup.
Describes how the system alerts users to events and the meaning of different notification indicators.
Explains how to temporarily halt module operations for maintenance or other tasks.
Covers tracking and replenishing essential reagents and consumables like pipette tips.
Instructions for loading new pipette tips into the module's drawers.
Provides instructions for replacing cuvette arrays, including indicator light meanings.
Guides users on how to replace reagent vials, including checking cap tightness.
Lists compatible MALDI targets and notes for their use.
Step-by-step guide for loading MALDI targets into the module, including barcode scanning.
How to safely stop the module's operation for maintenance or calibration.
Procedure for properly shutting down the IdentifA module after specimen processing is complete.
Procedures for handling and disposing of liquid and solid waste generated by the module.
Explains the importance and methods for cleaning and disinfecting the module components.
Lists recommended and compatible cleaning agents and disinfectants for the module.
Outlines different cleaning approaches: dry, wet, and combined cleaning techniques.
Details specific cleaning procedures for individual module components.
Procedures for cleaning up spills in specific areas of the module.
Guidelines for decontaminating the module after spills or contamination.
Outlines essential routine maintenance tasks for the module.
Describes the monthly and daily calibration procedures for the nephelometer.
Guides users on how to react to system alerts and errors promptly.
Lists common error codes, messages, and their corresponding resolution descriptions.
Evaluates the accuracy of the IdentifA module in picking designated colonies from culture plates.
Assesses the accuracy of organism identification using samples prepared by IdentifA.
Examines the consistency of organism identification results across modules, operators, and days.
Evaluates the module's ability to achieve expected identification at specified microbial suspension levels.
Assesses the potential for cross-contamination between samples within the IdentifA module.
Lists physical dimensions, weight, and environmental requirements for installing the module.